+49 9841 4038242

Ultraschall-Doppler Durchflussmessgerät, das an jeden Datenlogger oder bestehende Prozessleitsystem angepasst werden kann

Q-Flow Durchflussmessgerät

Das Q-Flow 25 ist ein anpassbares Ultraschall-Doppler Durchflussmessgerät, das an jeden Datenlogger oder bestehendes Prozeßleitsystem angeschlossen werden kann.
Die Ultraschall-Doppler Methode ist für offene Kanäle und teilgefüllte Rohre bestens geeignet. Auch für temporäre Anwendungen ist das Q-Flow 25 einsetzbar.

Durchflußüberwachung in Echt-Zeit

 

 

Arbeitsweise

Installed within the open channel, the sensor simultaneously uses ultrasound waves to measure the velocity of the liquid flow and pressure sensing technology to establish depth.

Pre-configured dimensions of the pipe or channel are used to determine the overall volume of flow.

The Q-Flow interface converts the raw data received from the sensor into recognised languages including MODBUS, SDI12 and frequency outputs are all optional.

The Q-Flow 25 interface can be connected to a data logger or integrated directly into a SCADA System via a PLC, giving the user full control.

key features

on board flow claculation

Works in rectangular, circular or trapezoidal pipes. Pulse output can be used for flow proportional sampling.

iN BUILT TEMPERATURE SENSOR

A built-in temperature sensor provides greater accuracy of measurement.

Market leading accuracy

Uses velocity adn depth to calculate the overall flow.

COST EFFECTIVE

Where required, the Q-Flow interface can be connected directly to the customers data management system negating the need for additional data loggers, transmitters and controllers.

product specification

VELOCITY SENSOR
Dual piezoelectric elements.

DEPTH SENSOR
Hydrostatic pressure.

INTEGRATED TEMPERATURE COMPENSATION
Titanium diaphragm isolated silicon sensor.

Physical
Sensor cable 10m as standard, up to 20m
if required.

Environmental
Sensor module protection: IP68.
Operating temperature: -20°C to +60°C.

Approvals
Version available with ATEX Zone 0 approval,
Sira 18ATEX2194X and IECEx SIR 18.0049X,
II 1G, Ex ia IIB T4 Ga, Ta = -40°C to +60°C.

PERFORMANCE – Velocity Sensor
Velocity range: 0.03m/s to 4.00m/s
(resolution 1mm/s).
Linearity: ±1%.
Velocity Sensor Accuracy: ±2.5% FS
(±1% in calibrated range 0.05m/s – 2.00m/s).

PERFORMANCE – Depth Sensor
Range: 0.0m to 3.5m (resolution 1.0mm).
Linearity: 0.1% BSL.
Accuracy: ±0.2% FS
(±0.1% in calibrated range 0.03m – 2.00m).

PERFORMANCE – Temperature Sensors
Range: -20°C to +60°C
Resolution: ±5°C

Version available with ATEX ia Zone 0 approval

Kontakt

Telefon:

+49 9841 4038242

Address:
Seegasse 12
91438 Bad Windsheim

Email:

kontakt@detectronic.org

Starten Sie Ihre Anfrage hier

Für Fragen füllen Sie unser Formblatt aus:

Detectronic - Germany © 2018 | HTML Sitemap | Datenschutz

Web design by Website Design Derby

  • Suche ...